FOREIGN TRADE IN THE LAST 5 YEARS:
LABORATORIOS OFTALMICOS S.A.S.

IMPORTS

  • - Records:
  • 252

  • - US$:
  • 3,797,512

EXPORTS

  • - Records:
  • 28

  • - US$:
  • 423,555

Top Imported Products

Products Reg. US$
INSTRUMENTOS Y APARATOS DE OFTALMOLOGÍA 29 471,820 65 %
ARTÍCULOS Y APARATOS DE PRÓTESIS 11 198,038 27 %
COMPARADORES LLAMADOS "ÓPTICOS", BANCOS COMPARADORES, BANCOS DE MEDIDA, INTERFERÓMETROS, C... 5 18,863 3 %
SILLONES DE PELUQUERÍA Y SILLONES SIMILARES, Y SUS PARTES 2 12,905 2 %
MOBILIARIO PARA MEDICINA, CIRUGÍA, ODONTOLOGÍA O VETERINARIA (POR EJEMPLO: MESAS DE OPERAC... 2 7,814 1 %
LOS DEMÁS ASIENTOS GIRATORIOS DE ALTURA AJUSTABLE 4 4,714 1 %

For more information request a free trial

Top Origin Countries

Countries Reg. US$
JAPÓN 22 345,387 48 %
HUNGRÍA 11 198,038 27 %
DINAMARCA 2 78,082 11 %
ESTADOS UNIDOS 10 37,689 5 %
SUIZA 4 32,773 5 %
PAÍSES BAJOS 5 12,610 2 %

For more information request a free trial

Shipping Details

With Veritrade you can see the details of the operations at the maximum level allowed by each country, resulting in the following.

Records
1 8/14/2023

9018500000 0 2 U 10,730.00 HAPAG-LLOYD JAPÓN DO 23-14384/ PO 457-T/PRODUCTO CAMARA RETINAL USO O DESTINO: OBTENCIONDE IMAGENES FOTOGRAFICAS DIGITALES Y VIDEO DEL FONDO DEL OJO (SUPERFICIE INTERIOR DEL OJO OPUESTA A LOS LENTES A TRAVES DE LA PUPILA) CAPTURAR IMAGENES DE LA RETINA Y E SEGMENTO ANTERIOR DEL OJO Y PARA PRESENTAR SUS DATOS AL PROFESIONAL DEL CUIDADO DE LOS OJOS, CON O SIN AGENTEMIDRIATICO PARA DILATACION DE LA PUPILA, PARA AYUDAR EN EL DIAGNOSTICOY MONITOREO DE LA PATOLOGIA RETINIANA. DIAGNOSTICO DE LA RETINA, EL DISCO OPTICO, LA MACULAY EL FONDO
2 7/10/2023

9018500000 0 2 U 2,714.00 MSC - MEDITERRANEAN SHIPP ING COMPANY JAPÓN DO.23-14311 / PO 450-T / PRODUCTO FOROPTERO USO O DESTINO: SE UTILIZAPARA MEDIR LA POTENCIA REFRACTIVA DE LOS OJOS Y COMPROBAR LAS FUNCIONES BINOCULARES. TÉCNICA DE DIAGNOSTICO: METODO SUBJETIVO DE REFRACCIONCODIGOS: 230200-04562123289626 SERIALES: AF9000785 / AF9000804 REF. 422369072 MARCA TOPCON. TIPO TEM MODELO VT-10 CANT. 2 U ORIGEN JP. INCLUYE CATALOGOS Y ACCESORIOS PARA SU NORMAL FUNCIONAMIENTO.
3 8/1/2023

9018500000 0 210 U 12.20 CMA CGM SUIZA DO.23-14363 / 442-M 445-M 451-M 455-M / 1-5 //PRODUCTO INYECTOR. USO ODESTINO: TODAS LAS LENTES REFRACTIVAS MONOFOCALES DE MECICONTUR-SALVOLAS QUE SE INDIQUE LO CONTRARIO EN LA CAJA PLEGABLE-ESTAN INDICADAS PARA SER IMPLANTADAS DENTRO DEL SACO CAPSULAR DEL OJO ADULTO TRAS LA EXTRACCION DE UN CRISTALINO CATARATOSO, MEDIANTE LA TECNICA DE EXTRACAPSULAR O FACOEMULSIFICACION. TECNICA DE DIAGNOSTICO: CIRUGÍA DE CATARATA. SIN SERIAL. LOTE: 22157D4 REF PROD: LP604590P REF. ACCUJECT TM PRO 2.1-1P REF. FV AJECT2.1P1 MARCA M
4 9/1/2023

9018500000 0 3 U 6,716.67 OCEAN NETWORK EXPRESS JAPÓN DO.23-14383 / 1-4 / 454-T // PRODUCTO CAMARA RETINAL. USO O DESTINO: INSTRUMENTO UTILIZADO PARA OBSERVAR Y FOTOGRAFIAR EL SEGMENTO POSTERIORDEL OJO, TIPO MIDRIATICO Y NO MIDRIATICO. TECNICA DE DIAGNOSTICO: EXPLORACIÓN DEL FONDO DEL OJO. SERIAL: Z35643 REF. 36000-91 MARCA TOPCON.MODELO TRC-NW8F. CANT. 1 U ORIGEN JP. INCLUYE LOS SIGUIENTES ACCESORIOS Y REPUESTOS: BRAZO DE SOPORTE PARA MESA (PARA INYECTAR FLUORESCEÍNA) REF. 1001N CANT. 1 U / RUEDAS PARA MESA ELÉCTRICA REF. 2025000107 MARCA: GROSS STOBIL CANT. 4 U / CA
5 10/13/2023

9018500000 0 2 U 5,931.00 MSC - MEDITERRANEAN SHIPP ING COMPANY JAPÓN DO 23-14440/PRODUCTO UNIDAD OFTALMICA. USO O DESTINO: EQUIPO UTILIZADOEN LA INDUSTRIA OFTALMOLÓGICA. TÉCNICA DE DIAGNOSTICO: NO APLICA. SERIALES:3559/ 3568 REF. SK42000066 MARCA TOPCON. MODELO IS-100. CANT.2 U ORIGEN JP. INCLUYE ACCESORIOS PARA SU NORMAL FUNCIONAMIENTO:UNIDADIS-100 SERIALES:3559/ 3568 REF:42-0000208 CANT. 1 U/ BRAZO PARA FOROPTER DE IS-100 SERIAL:03559/ 03568 REF: 1202282 CANT. 1 U / PROYECTOR SUPPORT REF: 1202206 CANT. 1 U/ LAMPARA DE LECTURA DE IS-100 REF: 42-0000214 CANT. 1 U/ SILLARECLINABLE AZ
6 10/13/2023

9018500000 0 1 U 31,600.00 CMA CGM JAPÓN DO 23-14440/PRODUCTO TOMOGRAFO DE COHERENCIA OPTICAL USO O DESTINO: APARATO DE TOMA ESPECIAL PARA OBSERVAR, FOTOGRAFIAR Y GRABAR LA IMAGEN YTOMOGRAFIA DE FONDO Y DE REPRESENTAR SU IMAGEN ELECTRONICA PARA EL DIAGNOSTICO EN 3D ESTA INDICADO PARA LA VISUALIZACION EN VIVO, AXIAL, IMAGENES DE CORTE TRANSVERSAL Y EN TRES DIMENSIONES Y LA MEDICION POSTERIOR DE LAS ESTRUCTURAS OCULARES, INCLUYENDO LA RETINA, LA CAPA DE FIBRAS NERVIOSAS DE LA RETINA, LA MACULA, Y EL DISCO OPTICO. ES DISEÑADO PARA SER UTILIZADO COMO DIAGNOST
7 10/13/2023

9018500000 0 1 U 25,000.00 MSC - MEDITERRANEAN SHIPP ING COMPANY JAPÓN DO 23-14440/PRODUCTO SISTEMA DE REFRACCION BINOCULAR USO O DESTINO:MEDIR LA POTENCIA DE REFRACCION ESFERICA Y CILINDRICA, ASI COMO LA DIRECCION DEL EJE DE ASTIGMATISMO DEL GLOBO OCULAR. MEDIR EL RADIO DE CURVATURA DE LA SUPERFICIE DE LA CORNEA. REALIZAR EXAMENES SUBJETIVOS DE AGUDEZA POR REFRACCION. REALIZAR MEDICIONES SUBJETIVAS COMO MANTENER LA VISION BINOCULAR. MEDIR LA POTENCIA DE REFRACCION Y LA FORMA DE LA CORNEA Y REALIZAR UNA MEDICION SUBJETIVA EN AMBOS OJOS AL MISMO TIEMPO. REALIZAR REFRACCION BINOCULAR, M
8 10/13/2023

9018500000 0 7 U 4,567.71 CMA CGM JAPÓN DO 23-14440/ PRODUCTO CAMARA DIGITAL USO O DESTINO: ESTAN DISEÑADAS PARA SU USO EN EL EXAMEN OFTALMOLOGICO DEL SEGMENTO OCULAR ANTERIOR, DESDE EL EPITELIO DE LA CORNEA HASTA LA CAPSULA POSTERIOR, SE UTILIZA PARA AYUDAR A DIAGNOSTICAR ENFERMEDADES O TRAUMATISMOS QUE AFECTAN LAS PROPIEDADES ESTRUCTURALES DEL SEGMENTO ANTERIOR DEL OJO TECNICA DE DIAGNOSTICO:EXPLORACIÓN DEL FONDO DEL OJO. SERIAL:AJ6003911 REF. 28504KD MARCA SIN MARCA MODELO DC-4 CANT. 1 U ORIGEN JP. INCLUYE ACCESORIOS PARASU NORMAL FUNCIONAMIENTO: ADAP

For more information request a free trial


Thousands of companies use VERITRADE to look for SUPPLIERS AND COMPETITORS